Nine Things You Must Know About Using Automatic Doors
一、About optional alarm probes
The performance of the automatic door alarm function depends on the performance of the alarm probe. The user should select an alarm probe according to the actual needs of the alarm. Most automatic door controllers are equipped with a pyrolytic alarm probe when they are delivered from the factory. If the alarm function is not used, the probe can be disconnected.
二、Alarm probe should be equipped with rain cover
The type of the output signal interface of the automatic door alarm probe should be a relay output interface, and the power supply voltage should be DC 12V-15V, otherwise it cannot be directly powered by this controller, and the power consumption of the probe should be ≤100 mA. According to the site conditions, multiple probes can be used (generally 1-2 are appropriate). Multiple probes should be connected in parallel. The probe should be protected from other heat sources or direct light. A rain cover should be installed above to prevent burns due to water leakage .
三、Switch direction adjustment
When the direction of opening and closing of the automatic door is found to be opposite, the wiring of the "V" and "W" terminals of the controller can be reversed; similarly, when the STOP display indicates the opposite direction, adjust the wiring in the same way.
四、Auto stop function setting
The automatic door automatic stop function can be set according to the door travel of the user. It is generally set to about 145 seconds when leaving the factory.
五、Controller failure should be repaired in a timely manner
When the automatic door controller fails, the doorway should be quickly contacted for maintenance, so as to avoid the impact of the expansion of the use of the door. Among the automatic doors repaired by our company, there are insufficient professional skills of non-professionals or small maintenance team maintenance personnel, and there are errors The condition of the line burned out accessories.
六、Automatic door controls should be kept clean
The automatic door controller should be kept clean to prevent water or other harmful substances from eroding; the use of organic solvents is strictly forbidden for cleaning the cabinet.
七、Automatic door cable core number is not less than 8 wires
The number of cable cores for automatic doors should generally not be less than 8 wires (in the past, 7 wires were not very reasonable). The door cable should not contain connectors.
八、The remote control should avoid electromagnetic interference sources
The remote control transmitter should keep the case to prevent squeezing vibration and falling into the water. Pay attention to check the battery voltage and replace it if necessary; when the remote control distance is too close, the battery should be replaced. The battery model is KC12V-23A. The remote control should be avoided as far as possible Source of electromagnetic interference.
九、The remote control cannot be replaced casually
The remote controller is not interchangeable according to the code encryption when it leaves the factory. When the user needs to change, the password can be changed by the manufacturer according to requirements.